Heat pump size calculator
Check assessed design heat loss against heat pump output at the same design conditions.
After you calculate
Check your heat pump capacity
Add your assessed heat loss, design temperatures and available output, then calculate to see your results.
Design heat required
Shown after calculationCapacity margin
Shown after calculationDesign load
Output comparison
Full calculation
Compares your assessed demand with the output available at your chosen conditions.
Understand your estimate
How it works
Check whether a heat pump’s available output covers the home’s assessed design heat loss. Choose an installer’s heat-loss figure directly, or use a professionally measured heat-transfer coefficient with the design temperatures. This tool does not guess heat loss from floor area or the age of the home.
Enter the indoor temperature, outdoor temperature and water flow temperature for the proposed design. Water flow temperature is the temperature supplied to the heating system. Use equipment output at those same conditions. Choose a published model test point only when the exact product and test temperatures match; otherwise use an assessed output supported by your installer.
A few good questions
Before youget started.
Understand this calculator, the figures to enter and the limits of your estimate.
Sources
- Energy Saving Trust: room heat-loss assessmentChecked on 13 October 2026
- Energy Saving Trust: heat pump output at design conditionsChecked on 13 October 2026
- MCS: measured heat transfer coefficient and property assessmentChecked on 13 October 2026
- Vaillant: aroTHERM Split published technical tableChecked on 14 October 2026
- Last checked
- 13 October 2026
EnergySums
Heat pump size calculator
United Kingdom · How it works
- Guide updated
- 13 October 2026
| Item | Value |
|---|---|
| Guide updated | 13 October 2026 |
How it works
Check whether a heat pump’s available output covers the home’s assessed design heat loss. Choose an installer’s heat-loss figure directly, or use a professionally measured heat-transfer coefficient with the design temperatures. This tool does not guess heat loss from floor area or the age of the home.
Enter the indoor temperature, outdoor temperature and water flow temperature for the proposed design. Water flow temperature is the temperature supplied to the heating system. Use equipment output at those same conditions. Choose a published model test point only when the exact product and test temperatures match; otherwise use an assessed output supported by your installer.
Formula
Use installer-assessed design heat loss directly, or professionally measured heat transfer coefficient × (indoor minus outdoor temperature) ÷ 1000. Available equipment output must be taken at the stated outdoor and flow temperatures. Margin = available output minus design load. No arbitrary age-band, area or oversizing factor is used.
A heat-transfer coefficient is the number of watts lost for each degree of temperature difference. Its unit is W/K, or watts per kelvin. A Celsius temperature difference has the same size as a kelvin difference. Multiply the coefficient by indoor minus outdoor temperature, then divide by 1000 to get kilowatts.
Kilowatts, written kW, measure heating power. Compare design load and available output in the same unit. A positive margin means output exceeds the entered load at those conditions. A negative margin means output is below it. The margin is not a recommended extra capacity or a guarantee that the whole system will work well.
The result keeps the selected conditions with its working. Use that record when discussing a quote. Do not replace a manufacturer output figure with the electrical input rating: heat delivered and electricity consumed are different quantities.
Worked example
These illustrative inputs are separate from your saved answers. Prices, use and performance are held constant for this worked scenario; they are not personal defaults.
Inputs used in this worked example.
- Indoor design temperature
- 21 °C
- Outdoor design temperature
- -3 °C
- Water flow design temperature
- 45 °C
- Heating assessment available
- Installer design heat loss
- Installer design heat loss
- 8 kW
- Equipment performance source
- My assessed performance
- Unit output at these design conditions
- 7 kW
| Item | Value |
|---|---|
| Indoor design temperature | 21 °C |
| Outdoor design temperature | -3 °C |
| Water flow design temperature | 45 °C |
| Heating assessment available | Installer design heat loss |
| Installer design heat loss | 8 kW |
| Equipment performance source | My assessed performance |
| Unit output at these design conditions | 7 kW |
- Design heat requirement
- 8 kW
- Available design output
- 7 kW
- Capacity margin
- -1 kW
| Item | Value |
|---|---|
| Design heat requirement | 8 kW |
| Available design output | 7 kW |
| Capacity margin | -1 kW |
- Design heat requirement
- Installer's room-by-room assessed design load= 8 kW
| Calculation | Formula with saved values | Result |
|---|---|---|
| Design heat requirement | Installer's room-by-room assessed design load | 8 kW |
Assumptions and limits
Use an installer heat-loss assessment or a measured heat-transfer study for this property. The coefficient must cover the intended building. Do not use a number chosen only to make a preferred unit appear large enough. Personal design values start empty; examples are not submitted defaults.
Published model output applies only at the stated air and water conditions, including humidity where recorded. Confirm the exact product against the linked maker table. The calculator does not interpolate between test points or infer seasonal performance. An assessed output is needed where the source does not match the proposed design.
A capacity margin alone does not assess room emitters, controls, hot-water requirements or safe installation. It is not a room survey or a sizing certificate. Display values are rounded while the calculation keeps unrounded figures. Incomplete or invalid edits preserve the previous valid estimate with a warning.
Country rules
Use the UK property assessment and the maker’s record for the product being considered. The source links and checked dates show where the method and published test values came from. They do not confirm that your home or a proposed installation has been assessed.
This capacity check does not use a tariff, grant amount or assumed running cost. A published output is evidence for its stated test conditions only. Keep those conditions beside the quote and ask the installer to explain any difference from the intended outdoor and water temperatures.
When to ask a professional
A qualified installer should assess each room, the heat emitters and equipment output at design conditions. Ask for the heat-loss report and the performance table used to choose the unit. Check that the quoted model is the same model shown in that table.
Bring the saved inputs and capacity margin to the installer. Ask them to explain any shortfall and how the complete system meets the design load. Follow the maker instructions and local installation requirements.
Questions and answers
| Question | Answer |
|---|---|
| Where do I get the input figures? | Use the actual electricity/fuel bill, smart-meter or inverter record, installer assessment/quote or manufacturer technical sheet. The help explains the units and boundaries; do not guess an unavailable coefficient. |
| What does the calculation include? | Use installer-assessed design heat loss directly, or professionally measured heat transfer coefficient x (indoor minus outdoor temperature) / 1000. Available equipment output must be taken at the stated outdoor and flow temperatures. Margin = available output minus design load. No arbitrary age-band, area or oversizing factor is used. |
| Is this a prediction or an assessment? | It calculates the entered scenario. Use an installer heat-loss assessment and the heat pump's rated output at your design temperatures. |
| How are missing figures handled? | Complete the required fields using your bill, equipment records or an installer assessment. Enter 0 only where a quantity is zero or a cost does not apply. |
Sources
| Source | Checked | Reference URL |
|---|---|---|
| Energy Saving Trust: room heat-loss assessment | 13 October 2026 | https://greenheattoolkit.energysavingtrust.org.uk/t/heat-pump-installers-toolkit/heat-pump-system-design/heat-loss-calculations-detailed-guidance/ |
| Energy Saving Trust: heat pump output at design conditions | 13 October 2026 | https://greenheattoolkit.energysavingtrust.org.uk/t/heat-pump-installers-toolkit/heat-pump-system-design/sizing-a-heat-pump/ |
| MCS: measured heat transfer coefficient and property assessment | 13 October 2026 | https://heatloadcalculator.mcscertified.com/docs/usage/property-information-page |
| Vaillant: aroTHERM Split published technical table | 14 October 2026 | https://professional.vaillant.co.uk/for-installers/products/arotherm-split-heat-pump-58752.html |