Window replacement energy savings calculator
Estimate annual window transmission savings from assessed U-values and heating degree days.
After you calculate
See your window savings and payback
Add your window heat-loss reduction, heating price and replacement cost, then calculate to see your results.
Annual energy saving
Shown after calculationSimple payback
Shown after calculationPurchased energy saved
Heat loss reduction
Full calculation
Uses the heat-loss reduction and installed cost you enter.
Understand your estimate
How it works
Estimate annual heating energy saved by replacing windows with a lower whole-window U-value. U-value measures how easily heat passes through a window, including its frame. Lower values mean less heat passes through under the same conditions. Use comparable ratings for the existing and proposed windows.
Enter the total area being replaced in square metres. Use heating degree days in Celsius-days from a local weather record or assessment. Degree days combine how cold it was and for how long, compared with a chosen base temperature. Keep that base consistent with the heat assessment.
Enter the heating system's efficiency fraction or heat pump COP, the price per kWh of purchased heating energy and the installed window quote. The result shows useful heat saved, purchased energy avoided, yearly cost saving and simple payback. It covers heat passing through the windows, rather than every possible effect of replacement.
A few good questions
Before youget started.
Understand this calculator, the figures to enter and the limits of your estimate.
Sources
- NRCan: whole-window U-value and heat transmissionChecked on October 14, 2026
- NRCan: annual heating degree days and home labellingChecked on October 14, 2026
- Last checked
- October 14, 2026
EnergySums
Window replacement energy savings calculator
Canada · How it works
- Guide updated
- October 14, 2026
| Item | Value |
|---|---|
| Guide updated | October 14, 2026 |
How it works
Estimate annual heating energy saved by replacing windows with a lower whole-window U-value. U-value measures how easily heat passes through a window, including its frame. Lower values mean less heat passes through under the same conditions. Use comparable ratings for the existing and proposed windows.
Enter the total area being replaced in square metres. Use heating degree days in Celsius-days from a local weather record or assessment. Degree days combine how cold it was and for how long, compared with a chosen base temperature. Keep that base consistent with the heat assessment.
Enter the heating system's efficiency fraction or heat pump COP, the price per kWh of purchased heating energy and the installed window quote. The result shows useful heat saved, purchased energy avoided, yearly cost saving and simple payback. It covers heat passing through the windows, rather than every possible effect of replacement.
Formula
Annual transmission heat saved = window area × (old U-value − new U-value) × heating degree days × 24 ÷ 1000. Purchased energy saved = useful heat saved ÷ heating efficiency fraction or COP. Price only the avoided purchased energy.
Use 0.90 for a heater with 90% efficiency. This field is already a fraction, so do not enter 90 or divide 0.90 by 100 again. For a heat pump, enter its assessed COP directly. COP is heat delivered divided by electricity used; a ratio of 3 means 3 kWh of heat per 1 kWh of electricity.
The factor 24 converts degree days to degree hours, and dividing by 1000 converts watts to kilowatts. Price the purchased energy in cents per kWh, then divide by 100 for Canadian dollars. A replacement with a higher U-value produces a negative heat and cost saving; the calculator does not turn that into a positive result.
Worked example
These illustrative inputs are separate from your saved answers. Prices, use and performance are held constant for this worked scenario; they are not personal defaults.
Inputs used in this worked example.
- Heating energy price
- My bill rate
- Heating energy unit price
- 30 c / kWh
- Total assessed window area
- 20 m²
- Existing whole-window U-value
- 3 W / m²K
- Replacement whole-window U-value
- 1.5 W / m²K
- Annual heating degree days
- 4000 °C-days / year
- Heating efficiency fraction or COP
- 1 kWh heat / input kWh
- Installed window price
- 5000 CAD
- Price conversion
- 100 pence or cents per currency unit
| Item | Value |
|---|---|
| Heating energy price | My bill rate |
| Heating energy unit price | 30 c / kWh |
| Total assessed window area | 20 m² |
| Existing whole-window U-value | 3 W / m²K |
| Replacement whole-window U-value | 1.5 W / m²K |
| Annual heating degree days | 4000 °C-days / year |
| Heating efficiency fraction or COP | 1 kWh heat / input kWh |
| Installed window price | 5000 CAD |
| Price conversion | 100 pence or cents per currency unit |
- Estimated annual saving
- $864.00
- Purchased energy saved
- 2,880 kWh/year
- Simple window payback
- 5.787 years
| Item | Value |
|---|---|
| Estimated annual saving | $864.00 |
| Purchased energy saved | 2,880 kWh/year |
| Simple window payback | 5.787 years |
- Annual transmission heat reduction
- 20 m² × (3 − 1.5) W/(m²·K) × 4,000 K·days × 24 h/day ÷ 1,000 W/kW= 2,880 kWh heat
- Avoided purchased energy
- 2,880 useful kWh ÷ 1 heat/input factor= 2,880 kWh
- Annual energy saving
- 2,880 purchased kWh × (30 c/kWh ÷ 100 c/CAD)= $864.00
| Calculation | Formula with saved values | Result |
|---|---|---|
| Annual transmission heat reduction | 20 m² × (3 − 1.5) W/(m²·K) × 4,000 K·days × 24 h/day ÷ 1,000 W/kW | 2,880 kWh heat |
| Avoided purchased energy | 2,880 useful kWh ÷ 1 heat/input factor | 2,880 kWh |
| Annual energy saving | 2,880 purchased kWh × (30 c/kWh ÷ 100 c/CAD) | $864.00 |
Assumptions and limits
Use whole-window values measured on a comparable basis. Glass-only values leave out the frame and cannot stand in for a whole-window rating. Match the area measurement to the products being compared so the same window is not counted twice.
The estimate excludes changes in air leakage, solar heat gains, cooling, shading and installation effects. It does not assess draughts, moisture, noise or comfort. Heating degree days describe the chosen weather period; they do not predict every future year.
Simple payback divides the entered installed price by positive annual energy savings. Zero or negative savings have no finite payback. It holds prices and performance constant and excludes finance, replacement and future changes. Existing fixed heating charges are not savings from lower consumption. Money is rounded only for display. Incomplete edits retain the last valid estimate with a warning.
Country rules
Canadian prices vary by province, utility and plan. Enter the heating energy price in cents per kWh, including applicable usage charges and tax. Convert a gas price per cubic metre using the matching bill energy content before entry.
Dividing a complete bill by consumption can include fixed fees that will not change after window replacement. Use the price for energy actually avoided. Source dates describe the recorded method or data; they do not verify your personal quote or window ratings.
When to ask a professional
Ask a qualified energy adviser or window installer to check the window area, whole-window ratings and local heating degree days. Ask which savings the quote attributes to heat transmission and which depend on air sealing or other work.
Confirm installation details, moisture control and any building requirements before proceeding. The calculator cannot inspect the opening, approve a product or confirm safe installation. Consider the complete project scope alongside the energy estimate when comparing quotes.
Questions and answers
| Question | Answer |
|---|---|
| Where should I find my inputs? | Use metered usage, published equipment documentation or an installer assessment that matches the conditions being compared. Do not use a nameplate maximum as measured average consumption. |
| Does this predict my future bill? | No. It estimates the entered scenario using its selected prices and performance. Weather, behaviour, price changes and equipment condition can change actual costs. |
| Can I use my own prices? | Yes. Use prices from your bill or quote, including applicable tax. Keep units consistent. Existing fixed supply charges are excluded unless the form explicitly asks for them. |
| Are the worked-example inputs defaults? | No. The worked example is a hand-checked illustration, not typical property data. Enter your own equipment and usage information. |